Above Ground Copper Cable Joint

Above Ground Copper Cable Joint

Type CJE 16/-

The Above Ground copper Cable Joint is designed for use on the Highways Agency's motorway communication infrastructure.  The CJE16/F is intended for use on the NMCS ducted non-armoured 40 pair cable system, accommodating loading coils and build-out capacitors.  The CJE16 facilitates jointing, terminating, interconnection of local cables and test access. The enclosure is moulded out of impact resistant polycarbonate providing an environmental seal to IP65, and a clear lid for non intrusive inspection and easy installation into an HA cabinet Type 609. 

 

Above Ground Copper Cable Joint

Features

  • Suitable for use on HA NMCS Non-Armoured cable (TR2150).
  • Easy of installation in standard HA cabinet Type 609
  • Designed to HA specification MCE 2249A
  • Fully tested to HA environmental specification TR2130
  • Vibration proof, cage clamp connectors accepting CSA 0.08-2.5mm2
  • Easy fitting of Local side if required
  • Modular construction, easy fitting of loading coils and build out capacitors
  • All terminations have test access and isolation
  • Local side, special connectors for (RS485) quad cables
  • Future proof design for use with DSL transmission technology

Cable joint Types:-

Type

Use

No. of cables to be accommodated

Details

16/1
Transmission side 40 pair joint
2 x 40 pair
Unloaded
16/2
Transmission side 40 pair joint

 

2 x 40 pair
As 16/1 with additional coil boards, 18 circuits loaded at 22mH
16/3
Transmission side 40 pair joint

 

2 x 40 pair
As 16/1 with additional coil boards, 6 circuits loaded at 88mH
16/4
Transmission side 40 pair joint

 

2 x 40 pair
As 16/1 with additional coil boards, 24 circuits loaded at 22mH
16/5
Transmission side 40 pair joint

 

2 x 40 pair
As 16/1 with additional coil boards, 18 circuits loaded at 22mH and 6 at 88mH
16L
Local side –
Local distribution
2x 40 pair
10 x quad
Attached to any of the above transmission joints

Above Ground Copper Cable Joint

The transmission side joint is supplied with a mounting frame to fit directly into a 609 cabinet replacing the plywood panel.  The local side joint is fitted to the rear of the frame picking up the through connector system.

The Local side mirrors all the connection on the 40 pair longitudinal cable.  All circuits terminating on the local side may be isolated from the longitudinal side by means of break jacks.

All loading coil and build out capacitor boards are connector coded to inhibit incorrect installation.

To aid installation all connectors are marked with all their respective pair numbers and colour.

Local Side (CJE16/L)