Back to Products List
Signalling Converters

Please select from the list below the product information you wish to see.

VH7400 Voice Highway
ASC300 Signalling Converter
ASC500 Signalling Converter
DTMF Signalling Convertor
Product Selector
Equipment Options

Analogue Signalling Converter - ASC300

Conversions

GEN-GEN

SSAC15A

Magneto Signalling

         or manual 2280Hz

ASC300

ASC300

Manual E&M

SSDC5A

SSAC15A

Manual 2280Hz

Manual E&M

SSDC5A

GEN-GEN


The Kenton Research analogue signalling converter ASC300 provides conversion of a single circuit from gen-gen (magneto) signalling to SSAC15A or manual 2280Hz signalling or to 2-wire audio plus E & M with manual or SSDC5A signalling. The unit can also convert from SSAC15A or manual 2280Hz signalling to SSDC5A or manual E & M signalling with 2-wire or 4-wire audio. The converter features simple installation and setup with a multicoder for major configuration settings and single links for other options. An internal overload protected source of ring current is incorporated and the unit is fitted with dc input current limiting. The ASC300 E & M leads physically interface to UK SSDC5A equipment and they can be link configured to operate with North American type 1 and type 2 standards. The ASC300RM is a plug in 48V dc powered extended eurocard module for mounting in the 19 inch mounting shelf 12E7K or equivalent BABT approved enclosure. The ASC300SA is a wall mounted unit mains powered from the supplied PU246D plug top power supply.

APPROVED FOR CONNECTION TO
THE TELECOMMUNICATIONS NETWORK




ASC300 SPECIFICATIONS

GEN INTERFACE Port 600 ohm 2-wire
maximum level to line 0dBm
4dB nominal loss to 2280Hz port
3dB nominal loss to E & M port 2-wire audio      
Signalling detector sensitivity 20v RMS 17-25 Hz
call signal 65v RMS @ 25 Hz nominal
E & M INTERFACE Audio 600 ohm link selectable 2 or 4-wire
maximum level to line 0dBm
4-wire audio 0dB nominal loss to 2280Hz port
2-wire audio 4dB nominal loss to 2280Hz port
Signalling link selectable for SSDC5A or manual operation
idle - open circuit
signal - earth via 1200R/1uF NSF or direct
SB (Signal battery) connected to -48V or open
SG (Signal ground) connected to 0V or open
2280Hz INTERFACE Line Circuit 600 ohm 4-wire 4dB gain
provision to increase gain by 4dB for direct connection
audio output level -4dBm nominal
audio input level 0dBm nominal
Signalling link selectable for SSAC15A or manual operation
output tone frequency 2280 +/- 1Hz
output tone leve -24 / -14 dBm +/- 1dB
detector operate level -3 to -29dBm
AC15A - tone on idle both directions
manual - tone on during signalling
PHYSICAL ASC300RM ASC300SA
Power -43 to -57V dc @ 140 mA 220 to 250V 50-60 Hz
Size 100 x 220 x 35.5 mm 160 x 135 x 45mm
Weight 0.26kg 0.5kg
Connector DIN41612 male row a fitted insulation displacement IDC
Mounting 11024B 3U 19 inch shelf stand alone wall mounted
APPROVAL BABT NS/4271/2/T/605092 NS/4271/2/T/605091

 

VH7400 Voice Highway
ASC300 Signalling Converter
ASC500 Signalling Converter
DTMF Signalling Convertor
Product Selector
Equipment Options
Back to Products List